2025/02/14 更新

写真a

アライ トシキ
新井 俊貴
Arai Toshiki
所属
千葉北総病院 循環器内科 助教
職名
助教
外部リンク

論文

  • Efficacy and safety of atrial fibrillation ablation in patients with aged 80 years or older. Letter to the editor (response to Kataoka N, et al.).

    Kenji Yodogawa, Yu-Ki Iwasaki, Nobuaki Ito, Toshiki Arai, Masato Hachisuka, Yuhi Fujimoto, Kanako Hagiwara, Hiroshige Murata, Yoshiyasu Aizawa, Wataru Shimizu, Kuniya Asai

    Heart and vessels   2025年1月

     詳細を見る

  • Efficacy and safety of atrial fibrillation ablation in patients with aged 80 years or older.

    Kenji Yodogawa, Yu-Ki Iwasaki, Nobuaki Ito, Toshiki Arai, Masato Hachisuka, Yuhi Fujimoto, Kanako Hagiwara, Hiroshige Murata, Yoshiyasu Aizawa, Wataru Shimizu, Kuniya Asai

    Heart and vessels   2024年9月

     詳細を見る

    記述言語:英語   掲載種別:研究論文(学術雑誌)  

    Atrial fibrillation (AF) is the most common cardiac arrhythmia observed in the elderly. Its prevalence rises with age, particularly in individuals over 80 years old. While catheter ablation has emerged as a first line therapy for the patients with symptomatic AF, evidence on its application in elderly patients remains controversial. This study aimed to assess safety and efficacy outcomes of AF ablation in patients aged ≥ 80 years. Consecutive 1327 patients who underwent a first pulmonary vein isolation (PVI) for AF were retrospectively analyzed. Patients aged ≥ 80 years (elderly group, n = 107) were compared with patients aged < 80 years (younger group, n = 1220). At 1-year follow-up, there was no significant difference in AF free rate between the elderly and the younger group (72.0% vs. 73.9%, P = 0.786). Regarding major complications, the elderly patients had a greater incidence of periprocedural stroke (1.9% vs. 0.1%, P = 0.018). The rates of cardiac tamponade, phrenic palsy, and vascular complications were not significantly different between the 2 groups. PVI for AF is effective in patients aged ≥ 80 years with a similar success rate, but periprocedural stoke risk was higher compared to the younger population.

    DOI: 10.1007/s00380-024-02458-7

    PubMed

    researchmap

  • Enlarged right atrium predicts pacemaker implantation after atrial fibrillation ablation in patients with tachycardia-bradycardia syndrome. 国際誌

    Toshiki Arai, Yu-Ki Iwasaki, Hiroshi Hayashi, Nobuaki Ito, Masato Hachisuka, Serina Kobayashi, Yuhi Fujimoto, Kanako Hagiwara, Hiroshige Murata, Kenji Yodogawa, Wataru Shimizu, Kuniya Asai

    International journal of cardiology. Heart & vasculature   49   101297 - 101297   2023年12月

     詳細を見る

    記述言語:英語   掲載種別:研究論文(学術雑誌)  

    INTRODUCTION: Although catheter ablation (CA) of tachycardia-bradycardia syndrome (TBS) in patients with atrial fibrillation (AF) is considered to be an effective treatment strategy, pacemaker implantations (PMIs) are often required even after a successful CA. This study aimed to elucidate the clinical predictors of a PMI after CA. METHODS: From 2011 to 2020, 103 consecutive patients diagnosed with TBS were retrospectively enrolled in the study. Among the 103 patients, 54 underwent a PMI and 49 CA of AF. During 47.4 ± 35.4 months after 1.4 ± 0.6 CA sessions, 37 (75.5%) of 49 patients were free from atrial arrhythmia recurrences. PMIs were performed in 11 patients (PMI group) and the remaining 38 did not receive a PMI (non-PMI group). RESULTS: When comparing the PMI and non-PMI groups, there were no differences in the basic mean heart rate (P = 0.36), maximum pauses detected by 24-hour Holter-monitoring (P = 0.61), and other clinical parameters between the two groups while the right atrial area index was larger (42.1 ± 24.0 vs. 21.8 ± 8.4 cm2/m2 P = 0.002) in the PMI group than non-PMI group. The ROC curve analysis showed that the optimal cutoff point of the ratio of the right atrial area index to the left atrial area index for predicting a PMI following CA was 0.812 (Sensitivity 72.7%, specificity 71.1%, positive predictive value 42.1%, negative predictive value 90.0%, diagnostic accuracy 71.4%, AUC = 0.81). CONCLUSION: Right atrial enlargement prior to CA was considered to be one of the risk factors for a PMI after CA of AF.

    DOI: 10.1016/j.ijcha.2023.101297

    PubMed

    researchmap

  • Efficacy of electrical isolation of the left atrial posterior wall depends on the existence of left atrial low-voltage zone in patients with persistent atrial fibrillation.

    Shunsuke Uetake, Mitsunori Maruyama, Noriyuki Kobayashi, Toshiki Arai, Yasushi Miyauchi

    Heart and vessels   37 ( 10 )   1757 - 1768   2022年10月

     詳細を見る

    記述言語:英語   掲載種別:研究論文(学術雑誌)  

    BACKGROUND: Modification of the low-voltage zone in the left atrium (LA-LVZ) in addition to pulmonary vein isolation (PVI) has not shown sufficient improvement in arrhythmia-free survival in patients with persistent atrial fibrillation (PerAF). Further, the effect of electrical posterior wall isolation (PWI) is controversial. We investigated the impact of existence of LA-LVZ on the outcome of patients undergoing additional PWI for PerAF. METHODS: A total of 347 patients with PerAF who underwent primary catheter ablation with LA-LVZ based strategy were retrospectively analyzed. Voltage mapping in the left atrium (LA) was performed during sinus rhythm. Additional LVZ ablation was performed in patients with LA-LVZ. The operators decided whether additional PWIs were to be performed. RESULTS: Of 347 patients, 108 had LA-LVZ. In the LVZ group, patients with additional PWI (N = 70) had higher rates of freedom from tachyarrhythmia recurrence than those without (77.1% vs. 42.1%, p < 0.001). Furthermore, even when patients were limited to those with LA-LVZ in areas other than the posterior wall (N = 85), PWI had higher success rates (80.9% vs. 42.1%, p < 0.001). In contrast, in patients without LVZ (N = 239), there was no significant difference in the rate of successful outcome between those with and without PWI (81.3% vs. 88.1%, p = 0.112). On the other hand, the patients with PWI had greater atrial tachycardia (AT) recurrence rate than those without PWI (10.0% vs. 2.5%, p = 0.003). CONCLUSIONS: PWI, in addition to PVI and LVZ modification, may improve single procedural outcomes in patients with PerAF who have LVZ, regardless of the distribution in the LA. A combination of voltage-guided ablation and PWI may be a simple, tailored, and effective ablation strategy.

    DOI: 10.1007/s00380-022-02069-0

    PubMed

    researchmap

  • Improvement in Quality of Life via Catheter Ablation for Atrial Fibrillation in Patients Undergoing Hemodialysis Therapy. 国際誌

    Masato Hachisuka, Hiroshi Hayashi, Yu-Ki Iwasaki, Nobuaki Ito, Toshiki Arai, Serina Kobayashi, Rei Mimuro, Yuhi Fujimoto, Eiichiro Oka, Kanako Hagiwara, Ippei Tsuboi, Hiroshige Murata, Teppei Yamamoto, Michio Ogano, Kenji Yodogawa, Meiso Hayashi, Wataru Shimizu

    CJC open   4 ( 9 )   748 - 755   2022年9月

     詳細を見る

    記述言語:英語   掲載種別:研究論文(学術雑誌)  

    BACKGROUND: Atrial fibrillation (AF) is the most common arrhythmia in patients undergoing hemodialysis (HD); AF lowers quality of life (QoL) and increases the risk of dialysis-related complications. The present study aimed to evaluate the effectiveness of AF ablation on the QoL in patients undergoing HD. METHODS: Nineteen patients undergoing HD (14 men, age 68 ± 8 years; 15 with paroxysmal AF) who underwent catheter ablation (CA) of AF were enrolled in the study. The Kidney Disease Quality of Life Short Form (KDQOL-SF) was assessed to evaluate the QoL of the HD patients at baseline and 6 months after the ablation. Ablation outcomes and procedural complications were evaluated and compared to those of 1053 consecutive non-HD patients who underwent AF ablation. RESULTS: The KDQOL-SF of the HD patients 6 months after the ablation showed an improvement in physical functioning (54 ± 23 to 68 ± 28, P < 0.01), general health perceptions (38 ± 17 to 48 ± 15, P < 0.01), and symptoms/problems (75 ± 21 to 84 ± 13, P = 0.02), compared to baseline. For intradialytic symptoms, dyspnea during HD significantly improved after the CA in the HD patients without AF recurrence (43% to 7%, P = 0.04), whereas the atrial tachyarrhythmias and hypotension during HD remained unchanged. During the follow-up period of 17 ± 13 months after the last procedure, the incidence of being arrhythmia-free was similar (HD patients, 79% vs non-HD patients, 86%, log-rank P = 0.82). No life-threatening complications occurred in any of the patients. CONCLUSIONS: CA of AF improves QoL in patients undergoing chronic HD therapy.

    DOI: 10.1016/j.cjco.2022.05.009

    PubMed

    researchmap

▼全件表示

MISC

  • Implantable Cardioverter Defibrillator Generator Replacement in the Octogenarian(タイトル和訳中)

    林 洋史, 土井田 祐子, 岡島 周平, 伊藤 紳晃, 新井 俊貴, 小林 芹奈, 蜂須賀 誠人, 藤本 雄飛, 萩原 かな子, 岡 英一郎, 村田 広茂, 相澤 義泰, 淀川 顕司, 岩崎 雄樹, 丸山 光紀, 清水 渉, 浅井 邦也

    日本循環器学会学術集会抄録集   88回   OJ02 - 9   2024年3月

     詳細を見る

    記述言語:英語   出版者・発行元:(一社)日本循環器学会  

    researchmap

  • Optimizing Ablation Sites in Recurrent Atrial Fibrillation Cases using Emphasize Settings(タイトル和訳中)

    岡島 周平, 藤本 雄飛, 岩崎 雄樹, 土井田 祐子, 伊藤 紳晃, 新井 俊貴, 蜂須賀 誠人, 萩原 かな子, 村田 広茂, 相澤 義泰, 淀川 顕司, 清水 渉, 浅井 邦也

    日本循環器学会学術集会抄録集   88回   PJ006 - 2   2024年3月

     詳細を見る

    記述言語:英語   出版者・発行元:(一社)日本循環器学会  

    researchmap

  • Electrocardiographic Features in the Early Differential Diagnosis of Cardiac Amyloidosis from Cardiac Sarcoidosis(タイトル和訳中)

    蜂須賀 誠人, 村田 広茂, 淀川 顕司, 土井田 祐子, 岡島 周平, 伊藤 紳晃, 新井 俊貴, 小林 芹奈, 藤本 雄飛, 萩原 かな子, 林 洋史, 相澤 義泰, 清水 渉, 浅井 邦也, 岩崎 雄樹

    日本循環器学会学術集会抄録集   88回   PJ053 - 1   2024年3月

     詳細を見る

    記述言語:英語   出版者・発行元:(一社)日本循環器学会  

    researchmap